The Mayze
24 is no longer being manufactured, however the QSM 288 can provide
the same functionality as the Mayze 24 or the Multi Access Router
with modem emulation can provide Async transmission over Broadband.
More information QSM 288
More Information Multi
Access Router
The Mayze 24 supports a range of modulation techniques, and provides
industry standard error correction and compression. It automatically
negotiates the best modulation scheme to use with the remote modem
on a call by call basis, and performs auto dial and auto answer.
The Mayze 24 also provides two levels of security.
Features
- V.21,V.22,V.22bis,V.23. compliant
- V.42 error correction
- V.42bis data compression
- Sync or Async operation
- DTE Port V.24/V.28 compatible
- Extended AT command set
- Password security
- Dial back security
- Separate command port
- Soft configurable
- Auto dial/auto answer V.25
- V.54 loop tests
- 2,400 bps 2 wire PSTN/leased
- Remote configuration
- Standalone or Network 16 rack options for maximum flexibility
- Integral power supply on standalone unit
- Network manageable from DomainView Network Management System
Multi-standard operation
For dial-up operation interworking with modems from other vendors
is critical. To ensure maximum connectivity with the minimum of
fuss, Mayze 24 supports industry standard modulation schemes ranging
from V.22bis which offers data transmission at 2400bps, down through
V.22, V.21 and V.23.
Error correction
When working over voice grade dial-up and lease line circuits error
correction is essential. For situations where the data is not itself
protected by an error correcting protocol, Mayze 24 offers industry
standard V.42 error correction. This offers error free data transmission
and ensures interworking with other modems supporting this standard.
For complete backward compatibility MNP Classes 2-4 are also supported.
Data compression
To allow you to make the most cost efficient use of dial-up or
lease line services, Mayze 24 provides V.42bis data compression.
This technique which works in real-time on the data can provide
impressive increases in effective throughput. In asynchronous modes
data throughput up to 8000bps in V.22bis can be achieved, this represents
over 300% efficiency. To allow for this the data interface on the
Mayze 24 can run at up to 19,200bps. Of course V.42bis is the recognised
standard for data compression so ensuring a high degree of interworking.
Again for backward compatibility purposes MNP Class 5 is also offered.
Configuration
The Mayze 24 has twelve pre-set factory configurations, and four
user entered configurations held in non-volatile memory. Configurations
can be loaded and modified locally via the DTE port or command port.
The modem's configuration can also be modified remotely and stored
in the Network 16 management card.
Auto dial auto answer
The Mayze 24 supports auto dial/auto answer via AT commands or
V.25bis protocol in both sync and async. 50 telephone numbers with
text, and alternative numbers can be stored.
Security
The Mayze 24 can be programmed to check Stored Passwords (Level
1) during call set up. Additionally the rackmount unit can also
perform a Level 2 Security Handshake with the Network 16 providing
Time of Day access control.
The Mayze 24 can also be configured for Dial back Security with
a maximum of fifty numbers and passwords being stored in the modem's
on board memory. For added network integrity the EP version, with
it's second line interface, can route the dial back call through
a separate connection. Dial back security can be used in conjunction
with Level 2 security providing an extensive network security mechanism.
Network 16 compatible
As a fully managed component in the Network 16 range of data transmission
products, the Mayze 24 is available either as a standalone unit
or as a rack card. It can be housed and managed in the Network 16
racking system alongside existing modem products, it occupies a
single slot in a Network 16 rack. In its standalone form, the Mayze
24 uses the same enclosure as the Syncro modems.
Both the standalone unit and rack card have LED's and front panel
buttons for loading configurations, invoking tests and monitoring
the interface status.
View data
sheet for the Mayze 24
For more information on our range of modems, please contact Marketing.
|